Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen:
https://hdl.handle.net/20.500.12394/14531
Titel: | Design of a Control and Monitoring System for Pollutants in a Handcrafted Footwear Factory |
Autor(en): | Mantari Ramos, Lizbett Nattaly Mayta Leon, Helder Alexis Huayta Uribe, Alem Cordova Sanchez, Hitan Orlando Huamanchahua Canchanya, Deyby Maycol |
metadata.dc.contributor.advisor: | Zárate Peña, Frank William |
Stichwörter: | Temperatura Control automático Mecatrónica |
Herausgeber: | Universidad Continental |
Erscheinungsdatum: | 2024 |
metadata.dc.date.available: | 23-Apr-2024 |
Zitierform: | Mantari, L., Mayta, H., Huayta, A., Cordova, H. y Huamanchahua, D. (2024). Design of a Control and Monitoring System for Pollutants in a Handcrafted Footwear Factory. Tesis para optar el título profesional de Ingeniero Mecatrónico, Escuela Académico Profesional de Ingeniería Mecatrónica, Universidad Continental, Huancayo, Perú. |
metadata.dc.identifier.doi: | https://doi.org/10.1109/ARACE56528.2022.00015 |
Zusammenfassung: | Autonomous systems provide a new approach to environmental quality control in the labour market, especially in jobs that expose the employee to concentrations of pollutants, which, if constantly exposed, can cause damage to the employee's health and well-being. Therefore, this work presents a system of control and monitoring of pollutants in an independent way for a handmade footwear factory. For the development of the design, the VDI 2206 methodology was used, where the technological information, control design and system integration are presented. All this will allow the system to perform a good collection of information of the main environmental parameters to then be displayed on an HMI screen in real time, also the system has a PLC controller to activate the air conditioning instruments according to the information received in order to maintain the maximum permissible parameters of pollutants, which are a temperature between 30 ° C and 35 ° C, a relative humidity between 30 % and 70 % and an exposure of VOC between 0.50 ppm and 0.70 ppm. In this way, the system prevents the occurrence of diseases caused by unintentional exposure to pollutants. |
metadata.dc.relation: | https://ieeexplore.ieee.org/document/9951124 |
Extension: | 1 página |
metadata.dc.rights.accessRights: | Acceso restringido |
metadata.dc.source: | Universidad Continental Repositorio Institucional - Continental |
Enthalten in den Sammlungen: | Tesis |
Dateien zu dieser Ressource:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
IV_FIN_112_TE_Mantari_Mayta_Huayta_Cordova_Huamanchahua_2024.pdf | Mantari Ramos, Lizbett Nattaly; Mayta Leon, Helder Alexis; Huayta Uribe, Alem; Cordova Sanchez, Hitan Orlando; Huamanchahua Canchanya, Deyby Maycol | 668.78 kB | Adobe PDF | Öffnen/Anzeigen |
IV_FIN_112_Autorización_2024.pdf Restricted Access | Autorización | 113.31 kB | Adobe PDF | Öffnen/Anzeigen Eine Dokumentkopie anfordern |
Informe_Turnitin.pdf Restricted Access | Informe de Turnitin | 1.75 MB | Adobe PDF | Öffnen/Anzeigen Eine Dokumentkopie anfordern |
Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.