Título: | Comparison Analysis of FIR, ARX, ARMAX by Least-Squares Estimation of the Temperature Variations of a Pasteurization Process |
Autor(es): | Del Carpio Ramirez, Sliver Ivan Ortiz Zacarias, Jhon Rodrigo Macuri Vasquez, Jalber Brayan Chamorro Quijano, Sario Angel Huamanchahua Canchanya, Deyby Maycol |
Asesor: | Coaquira Rojo, Carlos Alberto |
Palabras clave: | Pasteurización Control Temperatura Sensores |
Editorial: | Universidad Continental |
Fecha de publicación: | 2023 |
Fecha disponible: | 23-ene-2024 |
Cita bibliográfica: | Del Carpio, S., Ortiz, J., Macuri, J., Chamorro, S. y Huamanchahua, D. (2023). Comparison Analysis of FIR, ARX, ARMAX by Least-Squares Estimation of the Temperature Variations of a Pasteurization Process. Tesis para optar el título profesional de Ingeniero Mecatrónico, Escuela Académico Profesional de Ingeniería Mecatrónica, Universidad Continental, Huancayo, Perú. |
DOI: | https://doi.org/10.1109/UEMCON53757.2021.9666649 |
Resumen/Abstract: | This research shows the control of the pasteurization process in the dairy industry to obtain milk derivatives, which consists of applying heat at a certain temperature, obtaining the elimination of microorganisms, the preservation of nutrients, and product quality, however, when the temperature is exceeded, these benefits are lost. In addition, the PT-100 sensor was used to obtain a quick response and actuate a 2W-0.25-08 solenoid to avoid exceeding 62.8 C°. The development of the project shows the application of a microcontroller that obtained 3 types of samples of 430 data where the instability of the system was observed, so the FIR, ARX, and ARMAX methods were used to see the comparison of these and to be able to choose the most efficient for the process using the MatLab program. It was obtained that the ARMAX method is more effective for temperature control since it allows a fast signal from the sensor to the actuator. In conclusion, applying control with the ARMAX method will prevent the dairy company from exceeding the pasteurization temperature and thus obtain a quality product. |
Incluido en: | https://ieeexplore.ieee.org/document/9666649 |
Extensión: | 1 página |
Acceso: | Acceso restringido |
Fuente: | Universidad Continental Repositorio Institucional - Continental |
Aparece en las colecciones: | Tesis |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
IV_FIN_112_TE_Delcarpio_Ortiz_Macuri_Chamorro_Huamanchahua_2023.pdf | Resumen | 775.85 kB | Adobe PDF | Visualizar/Abrir |
IV_FIN_112_Autorizacion_2023.pdf Restricted Access | Autorización | 252.72 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Informe_Turnitin.pdf Restricted Access | Informe de Turnitin | 2.3 MB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems del Repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.