Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.12394/17066
Title: | Performance analysis of the Bess system: Contribution to the primary frequency regulation at C. H. Marañon-Huanuco |
Other Titles: | Análisis del desempeño del sistema Bess: Contribución a la regulación primaria de frecuencia en el centro de transmisión Marañón – Huánuco |
Authors: | Marin Huarcaya, Ivan Edwin Cairampoma Rodriguez, Gabriel Osiris |
metadata.dc.contributor.advisor: | Cairampoma Rodriguez, Gabriel Osiris |
Keywords: | Análisis de sistemas Systems analysis Battery Energy Storage System Almacenamiento de energía mediante baterías |
Publisher: | Universidad Continental |
Issue Date: | 2025 |
metadata.dc.date.available: | 25-Apr-2025 |
Citation: | Marin, I., & Cairampoma, G. (2025). Performance analysis of the Bess system: Contribution to the primary frequency regulation at C. H. Marañon-Huanuco [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental |
metadata.dc.identifier.doi: | https://doi.org/10.1109/ICOPESA61191.2024.10743330 |
Abstract: | The research aimed to evaluate the BESS system for primary frequency regulation at the Marañón hydroelectric plant. The research approach is quantitative, the method is deductive - descriptive, the type of research that was carried out is applied to a level of descriptive - correlational research and the design was non - experimental with longitudinal cut, frequency data of the system was used compared with the frequency of the speed regulator of the Marañón hydroelectric plant, according to the data obtained another comparison was made with the system frequency and the plant frequency after the installation of the BESS system, finally a simulation of the data obtained is carried out to see the behavior of the batteries during the power contribution time for primary frequency regulation. Concluding that, facing disturbances in the Peruvian power system, the BESS system is a good alternative when it comes to stabilizing the network, with the quick charge and discharge that positively influences the frequency, it was also possible to calculate the percentage of non - compliance that was reduced after the use of the BESS systems together with the economic benefits generated by the use of BESS systems. |
metadata.dc.relation: | https://ieeexplore.ieee.org/document/10743330 |
Extension: | p. 51 - 57 |
metadata.dc.rights.accessRights: | Acceso abierto |
metadata.dc.source: | Universidad Continental Repositorio Institucional - Continental |
Appears in Collections: | Tesis |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
IV_FIN_109_TE_Marin_Cairampoma_2025.pdf | Marin Huarcaya, Ivan Edwin ; Cairampoma Rodriguez, Gabriel Osiris | 2.53 MB | Adobe PDF | View/Open |
IV_FIN_109_Autorización_2025.pdf Restricted Access | Autorización | 106.89 kB | Adobe PDF | View/Open Request a copy |
Informe_Turnitin.pdf Restricted Access | Informe de Turnitin | 1.89 MB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License