Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.12394/17857
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorFlores Camayo, Jhosselin Madahies_PE
dc.contributor.authorGalvez Millan, Samuel Gandyes_PE
dc.contributor.authorPardo Chancasanampa, Jhosmel Willyes_PE
dc.contributor.authorFlores Camayo, Jhosselin Madahies_PE
dc.contributor.authorQuispe Anccasi, Carloses_PE
dc.date.accessioned2025-08-21T19:56:31Z-
dc.date.available2025-08-21T19:56:31Z-
dc.date.issued2025-
dc.identifier.citationGalvez, S., Pardo, J., & Flores, J., et al. (2025). Impact of Installing Lightning Arresters on Low Voltage Networks in Areas with High Lightning Incidence per Kilometer [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17857es_PE
dc.identifier.urihttps://hdl.handle.net/20.500.12394/17857-
dc.description.abstractThe concession area of Sociedad Eléctrica del Sur Oeste S.A. (SEAL) faces a significant challenge due to the high incidence of atmospheric discharges, ranging from 12 to 30 lightning strikes per square kilometer annually. These discharges result in critical failures in transformers and electrical networks. Current medium - voltage protections are insufficient to effectively mitigate electrical surges that damage secondary windings, leading to increased maintenance costs, service interruptions, and reduced system reliability. The presented article addressed these shortcomings through the implementation of Surge Protective Devices (SPDs), a technology already validated in Europe and Brazil. In critical areas such as Chuquibamba, Valle del Colca, Chococo, Orcopampa, and Huancarama, 1,300 SPDs were installed, distributed across three - phase and single - phase networks. The results demonstrated a significant reduction in failures, preservation of transformers, and low implementation costs — approximately $89.22 per three - phase SED and $44.61 per single - phase SED — totaling an investment of $28,119.00, which significantly reduces losses caused by the problem. Financial analysis confirmed the project’s profitability, with an Internal Rate of Return (IRR) of 14.9%, a Net Present Value (NPV) of $61,298.84, and a payback period of seven years. This viable and effective model reinforces the company’s commitment to innovation and energy efficiency, setting a precedent for expansion into other critical areas.es_PE
dc.formatapplication/pdfes_PE
dc.format.extentp. 286-289es_PE
dc.language.isoenges_PE
dc.publisherUniversidad Continentales_PE
dc.rightsinfo:eu-repo/semantics/openAccesses_PE
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/es_PE
dc.sourceUniversidad Continentales_PE
dc.sourceRepositorio Institucional - Continentales_PE
dc.subjectConductividad Eléctricaes_PE
dc.subjectElectrical Conductivityes_PE
dc.subjectRayos atmosféricoses_PE
dc.subjectAtmospheric rayses_PE
dc.subjectRentabilidades_PE
dc.subjectProfitabilityes_PE
dc.titleImpact of Installing Lightning Arresters on Low Voltage Networks in Areas with High Lightning Incidence per Kilometeres_PE
dc.title.alternativeImpacto de la Instalación de Pararrayos en Redes de Baja Tensión en Zonas con Alta Incidencia de Rayos por Kilómetroes_PE
dc.typeinfo:eu-repo/semantics/bachelorThesises_PE
dc.rights.licenseAttribution 4.0 International (CC BY 4.0)es_PE
dc.rights.accessRightsAcceso abiertoes_PE
dc.publisher.countryPEes_PE
thesis.degree.nameIngeniero Electricistaes_PE
thesis.degree.grantorUniversidad Continental. Facultad de Ingeniería.es_PE
thesis.degree.disciplineIngeniería Eléctricaes_PE
thesis.degree.programPregrado presencial regulares_PE
dc.identifier.journalIEEE Xplorees_PE
dc.identifier.doihttps://doi.org/10.1109/CPEEE64598.2025.10987447-
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.02.00es_PE
renati.advisor.dni70200351-
renati.advisor.orcidhttps://orcid.org/0000-0003-1098-3437es_PE
renati.author.dni71948981-
renati.author.dni72857514-
renati.author.dni70200351-
renati.author.dni23274196-
renati.discipline711046es_PE
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_PE
renati.typehttps://purl.org/pe-repo/renati/type#tesises_PE
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_PE
Appears in Collections:Tesis

Files in This Item:
File Description SizeFormat 
Informe_Turnitin.pdf
  Restricted Access
Informe de turnitin1.92 MBAdobe PDFView/Open Request a copy
IV_FIN_109_Galvez_Millan_Pardo_Chancasanampa_Flores_Camayo_Quispe_Anccasi_2025.pdfGalvez Millan, Samuel Gandy; Pardo Chancasanampa, Jhosmel Willy; Flores Camayo, Jhosselin Madahi; Quispe Anccasi, Carlos1.5 MBAdobe PDF
View/Open
IV_FIN_109_Autorización_2025.pdf
  Restricted Access
Autorización141.71 kBAdobe PDFView/Open Request a copy


This item is licensed under a Creative Commons License Creative Commons