Title: Impact of Height and Volume on the Seismic Reduction Coefficient for Elevated Tanks in Loreto: A Proposal for the Peruvian Standard E.030
Other Titles: Impacto de la altura y el volumen en el coeficiente de reducción sísmica para tanques elevados en Loreto: Una propuesta para la norma peruana E.030
Authors: Camarena Verastegui, Mirella Alexandra
Quispe Paitan, Gustavo
Quispe Paitan, Percy Julio
Laurencio Luna, Manuel Ismael
metadata.dc.contributor.advisor: Laurencio Luna, Manuel Ismael
Keywords: Construcciones antisísmicas
Earthquake-resistant buildings
Deformación
Deformation
Publisher: Universidad Continental.
Issue Date: 2025
metadata.dc.date.available: 21-Nov-2025
Citation: Camarena, M., Quispe, G., Quispe, P., & Laurencio, M. (2025). Impact of Height and Volume on the Seismic Reduction Coefficient for Elevated Tanks in Loreto: A Proposal for the Peruvian Standard E.030 [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://hdl.handle.net/20.500.12394/18465
metadata.dc.identifier.doi: https://doi.org/10.13189/cea.2025.130314
Abstract: The Loreto region of Peru faces a severe crisis in access to drinking water, with a large part of the population without adequate supply. Elevated tanks are a common solution, but present significant structural challenges in a seismically active area. The Peruvian standard E.030 does not specify a seismic reduction coefficient (R) for these tanks, leading to the use of foreign standards that do not fit local conditions. This increases the risk of structural failure, especially in inverted pendulum type geometry tanks, which endangers the safety and functionality of the water supply. This study proposes a new equation to estimate the most appropriate seismic reduction coefficient according to the height of the tank, taking into account the seismic conditions in Loreto. Simulations of seismic loads were carried out using the pushover method, evaluating the structural behaviour of 63 elevated tank models. The results show that as the tank height increases, the seismic reduction factor decreases, indicating a lower capacity of the structure to dissipate seismic loads. Models with larger volumes and heights exhibit more plastic behaviour, while smaller and stiffer tanks have lower ductility and reduction factor. The proposed equation, with a linear regression of the form y = - 0.064X + 9.598, provides an accurate tool to adjust the seismic reduction coefficient as a function of tank height. This proposal can be incorporated into the E.030 standard, improving the seismic design of elevated tanks in Loreto and other seismically active regions, and reducing the risk of structural failure during seismic events, ensuring a safer and more sustainable water supply.
metadata.dc.relation.uri: https://www.scopus.com/pages/publications/105002466580
Extension: [3] páginas.
metadata.dc.rights.accessRights: Acceso restringido
metadata.dc.source: Universidad Continental
Repositorio Institucional - Continental
Appears in Collections:Tesis

Files in This Item:
File Description SizeFormat 
IV_FIN_105_TE_Camarena_Quispe_Quispe_Laurencio_2025.pdfResumen805.52 kBAdobe PDFView/Open
IV_FIN_105_Autorización_2025.pdf
  Restricted Access
Autorización114.61 kBAdobe PDFView/Open Request a copy
Informe_Turnitin.pdf
  Restricted Access
Informe de Turnitin7.11 MBAdobe PDFView/Open Request a copy


This item is licensed under a Creative Commons License Creative Commons