Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12394/5522
Título: Endothelial dysfunction assessment by flow-mediated dilation in a high-altitude population
Autor(es): Calderón-Gerstein, W. S.
López-Peña, A.
Macha-Ramírez, R.
Bruno-Huamán, A.
Espejo-Ramos, R.
Vílchez-Bravo, S.
Ramírez-Breña, M.
Damián-Mucha, M.
Matos-Mucha, A.
Palabras clave: Endothelial dysfunction
Vasoreactivity
Brachial artery
High altitude
Flow-mediated vasodilation
Editorial: Universidad Continental
Fecha de publicación: sep-2017
Fecha disponible: 28-may-2019
Cita bibliográfica: Calderón, W., López, A., Macha, R., Bruno, A., Espejo, R., Vílchez, S., Ramírez, M., Damián, M., Matos, A. (2017). Endothelial dysfunction assessment by flow-mediated dilation in a high-altitude population. Vascular Health and Risk Management, 13(21), 421-426. https://doi.org/10.2147/VHRM.S151886
DOI: 10.2147/VHRM.S151886
Resumen/Abstract: Introduction: Endothelial function at high altitude has been measured only in populations that are genetically adapted to chronic hypoxia. The objective of this study was to evaluate endothelial dysfunction (ED) in a nongenetically adapted high-altitude population of the Andes mountains, in Huancayo, Peru (3,250 meters above sea level). Methods: Participants included 61 patients: 28 cases and 33 controls. The cases were subjects with hypertension, diabetes mellitus, obesity, or a history of stroke or coronary artery disease. Flow-mediated vasodilation (FMD) of the brachial artery was measured in the supine position, at noon, after 5 minutes of resting. The brachial artery was identified above the elbow. Its basal diameter was measured during diastole, and FMD was tested after 5 minutes of forearm ischemia. Intima–media complex in the right carotid artery was also determined. An increase in the artery’s baseline diameter <10% indicated a positive test. Endothelium-independent vasodilation was evaluated with sublingual nitrate administration. The intima–media complex in the right carotid artery was also measured.
Descripción: p. 421-426
Incluido en: https://www.dovepress.com/endothelial-dysfunction-assessment-by-flow-mediated-dilation-in-a-high-peer-reviewed-article-VHRM
Acceso: Acceso abierto
Fuente: Universidad Continental
Aparece en las colecciones: Artículos Científicos

Ficheros en este ítem:
No hay ficheros asociados a este ítem.


Los ítems del Repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.