Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12394/12970
Titolo: Design and performance study of the heat exchanger of a fin-based thermoelectric generator via numerical simulations
Autori: Cuyubamba Povez, Patrick Albino
Asto Evangelista, Joel
Almerco Ataucusi, Jean Raul
Valenzuela Lino, Yadhira Samhira
Huamanchahua Canchanya, Deyby Maycol
Moggiano Aburto, Nabilt Jill
metadata.dc.contributor.advisor: Huamanchahua Canchanya, Deyby Maycol
Parole chiave: Simulación
Calor
Editore: Universidad Continental
Data: 2022
metadata.dc.date.available: 31-mag-2023
Citazione: Cuyubamba, P., Asto, J., Almerco, J., Valenzuela, D., Huamanchahua, D. y Moggiano, N. (2022). Design and performance study of the heat exchanger of a fin-based thermoelectric generator via numerical simulations. Tesis para optar el título profesional de Ingeniero Mecatrónico, Escuela Académico Profesional de Ingeniería Mecatrónica, Universidad Continental, Huancayo, Perú
metadata.dc.identifier.doi: https://doi.org/10.1109/ICPSE56329.2022.9935347
Abstract: Climate change is a latent concern nowadays, so the ONU proposed to adopt new alternatives for obtaining energy through clean and renewable energies; that is why the TEG (Thermoelectric Generator) have been used in different industries and vehicles as they are a system that recovers and uses the waste heat from automobile exhaust gases for waste heat recovery; therefore, it is a method that allows improving energy efficiency. The present study aims to design and study the performance of the heat exchanger of a fin-based thermoelectric generator via numerical simulations. In this way, the geometry was performed using SolidWorks software. In addition, the meshing and boundary conditions were established in ANSYS Fluent to obtain the initial temperature distributions. Additionally, these initial temperature distributions serve as boundary conditions for ANSYS Thermal-Electric to obtain the semiconductor's final temperature distributions, voltage distributions, and electric current distributions. It was obtained as a result that the semiconductor's temperature distributions reached a voltage of 80 mV in 1 second of heat transfer. Also, the droplets fin-base TEG had an average temperature of 36.85 °C on the cold side and 163.3 °C on the hot side. Finally, it was concluded that the semiconductor’s final temperature distributions of the hot and cold side for the droplets fin-base TEG presented higher uniformity than the parallel plate fin-base TEG.
metadata.dc.relation: https://ieeexplore.ieee.org/document/9935347
Estensione: 2 páginas
metadata.dc.rights.accessRights: Acceso restringido
metadata.dc.source: Universidad Continental
Repositorio Institucional - Continental
È visualizzato nelle collezioni:Tesis

File in questo documento:
File Descrizione DimensioniFormato 
IV_FIN_112_Autorización_2022.pdf
  Restricted Access
Autorización173.85 kBAdobe PDFVisualizza/apri Request a copy
IV_FIN_112_TE_Cuyubamba_Asto_Almerco_Valenzuela_Moggiano_2022.pdfResumen2.67 MBAdobe PDF
Visualizza/apri


Tutti i documenti archiviati in DSpace sono protetti da copyright. Tutti i diritti riservati.