Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12394/13787
Título: Self-Built Houses in a Peruvian Andean City: Seismic Vulnerability and Seismic Behavior
Autor(es): Romero Huaman, Jordan Peter
Flores Rojas, David Anderson
Nizama Mallqui, Jose Luis
Valenzuela Inga, Albert Jorddy
Benito Zuñiga, Juan Gabriel
Estrada Porras, Franz Emmanuel
Asesor: Estrada Porras, Franz Emmanuel
Palabras clave: Factores de riesgo
Teoría de las estructuras
Sismos
Editorial: Universidad Continental
Fecha de publicación: 2023
Fecha disponible: 12-ene-2024
Cita bibliográfica: Romero, J., Flores, D., Nizama, J., Valenzuela, A., Benito, J. y Estrada, F. (2023). Self-Built Houses in a Peruvian Andean City: Seismic Vulnerability and Seismic Behavior. Tesis para optar el título profesional de Ingeniero Civil, Escuela Académico Profesional de Ingeniería Civil, Universidad Continental, Huancayo, Perú
DOI: https://doi.org/10.13189/cea.2023.110619
Resumen/Abstract: The Mantaro Valley in Peru has experienced a seismic silence lasting 54 years, indicating a significant likelihood of a major seismic event occurring. Moreover, the rapid increase in the problematic practice of self-construction, mainly using clay frame structures with infill masonry walls materials, has rendered the area highly susceptible to a seismic disaster, raising concerns specifically for the Huancán district. Thus, the main aim of this study was to assess the seismic vulnerability of 30 houses in the Huancán district by employing a questionnaire based on the INDECI methodology. The structural program (ETABS) was employed. Additionally, the seismic behavior of each house was evaluated through analytical analysis using structural calculation software. The findings revealed that 40% of the houses exhibited a very high vulnerability, 50% demonstrated an increased exposure, and 10% displayed a moderate vulnerability. The most influential factors contributing to this vulnerability were irregularities in the floor plan, height, and mass distribution of the houses. Furthermore, it was observed that the homes suffered from inadequate wall density in the X direction, negatively impacting compliance with standards related to wall density, maximum axial stress, crack control, and inter-story drift. Ultimately, the Huancán district exhibits a 90% vulnerability level classified as "high" and "very high", highlighting significant structural deficiencies such as house wall flexibility. It underscores the urgent need for authorities to implement preventive measures, including structural reinforcements and enhanced control in risk management practices.
Incluido en: https://www.hrpub.org/journals/article_info.php?aid=13569
Extensión: p. 3488-3504
Acceso: Acceso abierto
Fuente: Universidad Continental
Repositorio Institucional - Continental
Aparece en las colecciones: Tesis

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Informe_Turnitin.pdf
  Restricted Access
Informe de Turnitin6.64 MBAdobe PDFVisualizar/Abrir  Request a copy
IV_FIN_105_Autorización_2023.pdf
  Restricted Access
Autorización143.39 kBAdobe PDFVisualizar/Abrir  Request a copy
IV_FIN_105_TE_Romero_Flores_Nizama_Valenzuela_Benito_Estrada_2023.pdfRomero Huaman, Jordan Peter; Flores Rojas, David Anderson; Nizama Mallqui, Jose Luis; Valenzuela Inga, Albert Jorddy Albert; Estrada Porras, Franz Emmanuel4.2 MBAdobe PDF
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons