Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12394/14509
Título: Mechanical and Electronic Design of a Prototype Lower Limb Prosthesis for Transfemoral Amputation
Autor(es): Taza Aquino, Yerson
Quintanilla Mosquera, Iraiz Lucero
Ortiz Zacarias, Jhon Rodrigo
Beraun Espíritu, Manuel Michael
Arzapalo Bello, Ruben
Coaquira Rojo, Carlos Alberto
Asesor: Coaquira Rojo, Carlos Alberto
Palabras clave: Diseño
Amputación transfemoral
Análisis de estrés
Editorial: Universidad Continental
Fecha de publicación: 2024
Fecha disponible: 22-abr-2024
Cita bibliográfica: Taza, Y., Quintanilla, I., Ortiz, J., Beraun, M., Arzapalo, R. y Coaquira, C. (2024). Mechanical and Electronic Design of a Prototype Lower Limb Prosthesis for Transfemoral Amputation. Tesis para optar el título profesional de Ingeniero Mecatrónico, Escuela Académico Profesional de Ingeniería Mecatrónica, Universidad Continental, Huancayo, Perú.
DOI: https://doi.org/10.1109/UEMCON54665.2022.9965649
Resumen/Abstract: Abstract—In South America, there are few companies that are interested in the creation of prostheses and this, together with the little technological progress, makes patients with transfemoral amputation unable to perform their work. For this reason, the objective of this research is to design a prototype of a lower limb prosthesis for transfemoral amputation that helps the patient's mobility recovery, preventing the wear of the functional knee where an ergonomic design was considered for the patient's comfort. On the other hand, muscular sensors (EMG) were used to detect the intension of the movement, and triaxial accelerometers that capture the movement disturbances in the three axes X, Y, Z. The mechanical design was submitted to the Von Mises stress analysis simulation, these tests were performed in the SolidWorks software and the electronic circuit design was simulated in the Proteus software, where a correct interaction between the different sensors with the actuators of the prosthesis was achieved, in this way, the VDI 2206 methodology was applied. In the results it was possible to simulate the movements of the ankle by the implementation of the Stewart mechanism, also the pieces of the structure were subjected to an analysis where it is shown that efficiently support 68 kg this is related to the height of 165 cm. Finally, it was obtained that the suitable material is aluminum alloy 6061 T-6.
Incluido en: https://ieeexplore.ieee.org/document/9965649/
Extensión: 16 páginas
Acceso: Acceso abierto
Fuente: Universidad Continental
Repositorio Institucional - Continental
Aparece en las colecciones: Tesis

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IV_FIN_112_TE_Taza_Quintanilla_Ortiz_Beraun_Arzapalo_Coaquira_2024.pdfTaza Aquino, Yerson; Quintanilla Mosquera, Iraiz Lucero; Ortiz Zacarias, Jhon Rodrigo; Beraun Espíritu, Manuel Michael; Arzapalo Bello, Ruben; Coaquira Rojo, Carlos Alberto1.7 MBAdobe PDF
Visualizar/Abrir
IV_FIN_112_Autorización_2024.pdf
  Restricted Access
Autorización342.5 kBAdobe PDFVisualizar/Abrir  Request a copy
Informe_Turnitin.pdf
  Restricted Access
Informe de Turnitin2.71 MBAdobe PDFVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons