Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/20.500.12394/15613
Título: Influence of Vertical Geometric Irregularity on the Seismic Response of High-Rise Buildings Equipped with Base Isolation System
Autor(es): Olivera Perez, Romel Moises
Julcarima Coca, Thalia Leticia
Torpoco Lopez, Lovell Wilde
Laurencio Luna, Manuel Ismael
Asesor: Laurencio Luna, Manuel Ismael
Palabras clave: Construcciones antisísmicas
Edificios
Geometría
Editorial: Universidad Continental
Fecha de publicación: 2024
Fecha disponible: 27-sep-2024
Cita bibliográfica: Olivera, R., Julcarima, T., Torpoco, L. y Laurencio, M. (2024). Influence of Vertical Geometric Irregularity on the Seismic Response of High-Rise Buildings Equipped with Base Isolation System. Tesis para optar el título profesional de Ingeniero Civil, Escuela Académico Profesional de Ingeniería Civil, Universidad Continental, Huancayo, Perú.
DOI: https://doi.org/10.13189/cea.2024.121312
Resumen/Abstract: In the year 2022 according to the United Nations, the world population is three times larger than the twentieth century, which affects the demand for land and consequently the cost per m2 increases. Likewise, it requires occupants to choose to build high-rise buildings to maximize the area acquired, consequently most structures require huge shear walls that increase the cost in steel, and in turn reduce the profitability of real estate for lack of aesthetic spaces on the floors. Now, recent architectural models do not allow regular structures, consequently, different irregularities occur. The present work develops the influence of vertical geometric irregularity in high-rise buildings with base isolation system, by which the researchers, modellers and designers, carried out the analysis of a regular pattern model (MPAT) based on shear walls, columns and beams against 12 different models, presented in their structural configuration different vertical geometric irregularities, consisting of 20 floors. It was analyzed by means of the seismic properties established in the Peruvian regulation of buildings norm E.030 and E0.31, providing with rigidity, resistance, ductility to the structure, likewise the elements of isolation of base of the type Elastomeric LRB and Slider were placed, which were developed with a nonlinear analysis time history with a total of 7 pairs of seismic registrations. Finally, it was observed in the displacement analysis that the irregular structures compared to the regular structure do not present a variation greater than 3.14%. Similarly, drifts between floors were analysed in which the models M1T3, M2T3, M3T3, and M4T3 presented greater drifts compared to the regular model, obtaining in the model M4T3 an increase in the drift of 56. 74%. On the other hand, in the accelerations per level, the M2T3 model obtained an increase of 60.63% compared to the standard model. Finally in the analysis of energy dissipation with seismic isolators, the M4T3 model dissipates 92.84% of energy generated in the structure, consequently the seismic effect is dissipated directly by the base isolators.
Incluido en: https://www.hrpub.org/journals/article_info.php?aid=14167
Extensión: p. 2091 - 2115
Acceso: Acceso abierto
Fuente: Universidad Continental
Repositorio Institucional - Continental
Aparece en las colecciones: Tesis

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IV_FIN_105_TE_Olivera_Julcarima_Torpoco_Laurencio_2024.pdfOlivera Perez, Romel Moises; Julcarima Coca, Thalia Leticia; Torpoco Lopez, Lovell Wilder; Laurencio Luna, Manuel Ismael3.77 MBAdobe PDF
Visualizar/Abrir
IV_FIN_105_Autorización_2024.pdf
  Restricted Access
Autorización117.54 kBAdobe PDFVisualizar/Abrir  Request a copy
Informe_Turnitin.pdf
  Restricted Access
Informe de Turnitin3.42 MBAdobe PDFVisualizar/Abrir  Request a copy


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons